    On the left are some pressure switches.
    When there is a call for heat, and the inducer starts, if , after 1-2 minutes, the inducer shuts off and pressure switch code comes on, The pressure switch is not closing.

     To test this, recycle the furnace. Remove the wires from the pressure switch.

    Water pressure switch stuck open

     On a call for heat, the inducer should start.  While the inducer is running, short the wires going to the pressure switch with a jumper.  Do not short the pressure  switch itself.  The furnace  should start.

    How to test furnace pressure switch

  • Furnace pressure switch replacement
  • Pressure switch stuck open goodman
  • Water pressure switch stuck open
  • How to fix furnace pressure switch stuck open
  •  Caution: the burners may not burn properly.  be ready to pull the power.  
    If the unit starts, there is a pressure problem.  It is not necessarily the pressure switch!

    How to fix pressure switch open with inducer on

     The pressure  switch is an indicator of pressure problems in the furnace.  Check the tubing from the inducer.  It should be clear. Also the fittings that the tubing fit into should be clear.  Note: the pressure switch fitting may have a restrictor inside, do not remove.

     
    Other problems that could cause the pressure switch to n